在线求分析x3850 DSA故障原因!!!!!!
Report HighlightsMessage
The system has experienced a failure. Check the diagnostic panel LEDs for more information.
See the advanced system management event log for system information.
View the diagnostic panel LEDs for more information.
Call service for assistance with the non-maskable interrupt.
A PCI Adapter Fault has been detected. Check PCI connections.
A ServeRAID adapter is present but ServeRAID Manager is not installed.ServeRAID Manager may be obtained from the IBM Support site.
A ServeRAID 8i, 8s, 8k/8k-l or 7t is present, but there is a driver and firmware mismatch. Please update your device driver or install ServeRAID Manager including the ServeRAID Manager Agent to allow DSA to capture information.
System Event Log collection truncated after 1024 log entries.
Application Event Log collection truncated after 1024 log entries.
IPMI09/09/2010 13:39:17) System chassis 1 (Critical Interrupt - NMI State): Assertion: Software NMI.
IPMI08/08/2010 13:56:08) Power supply 1 (Power Supply - PS 1R Fault): Assertion: Power Supply Failure detected.
IPMI08/08/2010 13:56:08) Power supply 1 (Power Supply - PS 1R Status): Assertion: Power Supply AC lost.
IPMI:(08/08/2010 13:56:08) Power supply 1 (Power Supply - PS 1R Status): Assertion: Power Supply Failure detected.
IPMI:(01/01/1970 00:00:00) (OEM SMI No Time Stamp): SMI Event/Error: SMI PCI Event / Error. PERR: Master Read Parity Error (Primary Interface of PCI-to-PCI Bridge). Chassis Number 1. Slot Number 4. Bus Number 8. Device ID 8978. Vendor ID 4215. Status Register 49968. Revision Number 0. [i=s] 本帖最后由 yufeng_fly 于 2010-9-9 14:56 编辑 [/i]
Light Path
LED Settings
[table=80%]
[tr][td=1,1,25%]LED[/td][td=1,1,25%]Instance[/td][td=1,1,25%]Current State[/td][td=1,1,25%]Location[/td][/tr]
[/table]
NMI 1 on Not Available
Non-Redundant Power 1 off Not Available
Over Specification 1 off Not Available
PCI Adapter Fault 1 on Not Available
PCI-X 1 off Not Available
Power Fault 1 off Not Available
RAID Fault 1 off Not Available
Rear Fault 1 off Not Available
Rear Fault 2 off Not Available
Rear Fault 3 off Not Available
Sebring 1 off Not Available
SP Fault 1 off Not Available
Super IO Fault 1 off Not Available
System Error 1 on Not Available
System Information 1 on Not Available
System Log 1 off Not Available
Temperature Over Specification 1 off Not Available
VRM 4 off Not Available
VRM 5 off Not Available
VRM Fault 1 off Not Available 有Software NMI 报错, 在这之前机器都能正常工作吗?做过什么操作吗? 电源 PCI设备都报错,LZ是不是新加过设备? 话说 `..
LZ能不能说说具体的操作过程`... 升级微码后运行至现在一切正常。
页:
[1]