2007-9-27 15:20
53190180
AS/400挂接3580磁带机备份出现这样的问题?高手指点....
RSTOBJ OBJ(INI) SAVLIB(BANKDTAE) DEV(TAP05)
Interface error while using device TAP05.
System object TAP05 partially damaged. Internal dump ID . Error class 0,
device number X'0000'.
Save or restore operation ended unsuccessfully.
Message ID . . . . . . : MCH1668
Date sent . . . . . . : 09/27/07 Time sent . . . . . . : 13:24:14
Message . . . . : System object TAP05 partially damaged. Internal dump ID .
Error class 0, device number X'0000'.
Cause . . . . . : This partially damaged system object TAP05 has an error
class 0 and a device number X'0000'. Error class indicates how damage was
detected:
0000-previously marked damage;
0001-detected abnormal condition;
0002-logically invalid device sector;
0003-device error.
for error class 0003, the device number identifies the failing device, or
contains zero if main storage is damaged.
Message . . . . : *Attention* Interface error: Tape unit TAP05 (resource
TAP05) or IOP CMB01.
Cause . . . . . : Power interruption, electrical noise, improper connection
between hardware components, contact corrosion, electronic component or
terminating plug failure.
Recovery . . . : If the attached device is an external device, do the
following:
-- Ensure that the device has power.
-- Ensure that the external signal cable is properly connected and is not
damaged.
-- Ensure that a terminating plug is attached to the device end of the
external signal cable.
If no problems were found and corrected, press F14 and report the problem.
Technical description . . . . . . . . : The IOP or the tape unit detected an
error when a command or data was being transferred to/from the IOP, or the
IOP addressed the tape unit and the tape unit did not respond. Tape unit
TAP05 (resource TAP05) is attached to IOP resource CMB01.
Device type . . . . . . . . . . . . . : 3580
Reference code . . . . . . . . . . . : X'9100'
Product Activity Log ID . . . . . . . : X'00432A1E'
Problem log ID . . . . . . . . . . . : 0727046019
2007-9-27 15:41
老农
Message . . . . : *Attention* Interface error: Tape unit TAP05 (resource
TAP05) or IOP CMB01.
Cause . . . . . : Power interruption, electrical noise, improper connection
between hardware components, contact corrosion, electronic component or
terminating plug failure.
Recovery . . . : If the attached device is an external device, do the
following:
-- Ensure that the device has power.
-- Ensure that the external signal cable is properly connected and is not
damaged.
-- Ensure that a terminating plug is attached to the device end of the
external signal cable.
If no problems were found and corrected, press F14 and report the problem.
2007-9-28 10:09
小菜归来
as400这样的高级货为什么连接个磁带机,不考虑用个带库?
2008-1-6 21:27
hahawang
换盘磁带试?
2008-1-25 13:43
qingzhou
如果是磁带库设备:
1。关闭磁带库设备电源;
2。删除TAP05 JOBD,然后在系统值QAUTOCFG=1前提下,打开磁带库设备电源,让系统自动检测磁带库找回TAP05 JOBD,如不行,就用以前系统全备份的磁带回复TAP05 JOBD。
如以上方法还是不行,
3。关闭磁带库设备电源后,重新插拔磁带库后面的SCSI连接线,有时松动造成一些物理故障。
再不行,
4。换新带子试;
再不行,
CALL 800硬件报修。。。
如果是磁带机设备:
1。删除TAP05 JOBD,然后在系统值QAUTOCFG=1前提下,IPL,让系统自动检测磁带库找回TAP05 JOBD。
2。如不行,就用以前系统全备份的磁带回复TAP05 JOBD。
3。保证JOBD正常后,如果还无法正常工作,换盒新磁带试试?
4。再不行,只好CALL 800硬件报修。
[[i] 本帖最后由 qingzhou 于 2008-1-31 12:33 编辑 [/i]]