2008-1-2 18:56
乐之陶
oracle启动报错.
控制文件有问题.
2008-1-2 19:02
乐之陶
:P os:5305
数据放在共享盘阵上,出现这种问题是由于一个lun前两天出现了问题,经处理后正常了,数据库不是用的裸设备
2008-1-2 19:09
小猪
OS里面有啥报错哈.:lol
2008-1-2 19:26
kettyalx
:o ..
[[i] 本帖最后由 kettyalx 于 2008-1-2 19:29 编辑 [/i]]
2008-1-2 19:31
乐之陶
ds4700开始有报错:
Date/Time: 12/29/07 3:24:40 PM
Sequence number: 136
Event type: 2250
Event category: Failure
Priority: Critical
Description: Logical Drive failure
Event specific codes: 0/0/0
Component type: Logical Drive
Component location: Logical Drive Oracle_data3
Logged by: Controller in slot A
Raw data:
4d 45 4c 48 02 00 00 00 88 00 00 00 00 00 00 00
50 22 2d 01 38 f6 75 47 00 00 00 00 00 00 00 00
00 00 00 00 02 00 00 00 00 00 00 00 02 00 00 00
0d 00 00 00 0d 00 00 00 18 00 00 00 00 4f 00 72
00 61 00 63 00 6c 00 65 00 5f 00 64 00 61 00 74
00 61 00 33 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 01 00 00 00 00 00 00 00
Date/Time: 12/29/07 3:17:30 PM
Sequence number: 105
Event type: 222D
Event category: Internal
Priority: Critical
Description: Drive manually failed
Event specific codes: 0/0/0
Component type: Drive
Component location: Enclosure 0, Slot 10
Logged by: Controller in slot B
Raw data:
4d 45 4c 48 02 00 00 00 69 00 00 00 00 00 00 00
2d 22 41 21 8a f4 75 47 0a 00 10 00 00 00 00 00
a3 00 00 00 00 00 00 00 01 00 00 00 04 00 00 00
01 00 00 00 01 00 00 00 00 00 00 00 0a 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 01 00 00 00 00 00 00 00
[[i] 本帖最后由 乐之陶 于 2008-1-2 19:34 编辑 [/i]]
2008-1-2 19:35
乐之陶
主机报错
# errpt
IDENTIFIER TIMESTAMP T C RESOURCE_NAME DESCRIPTION
E86653C3 1229152007 P H LVDD I/O ERROR DETECTED BY LVM
E86653C3 1229152007 P H LVDD I/O ERROR DETECTED BY LVM
C1348779 1229152007 I O SYSJ2 LOG I/O ERROR
E86653C3 1229152007 P H LVDD I/O ERROR DETECTED BY LVM
EA88F829 1229152007 I O SYSJ2 USER DATA I/O ERROR
E86653C3 1229152007 P H LVDD I/O ERROR DETECTED BY LVM
E86653C3 1229151907 P H LVDD I/O ERROR DETECTED BY LVM
E86653C3 1229151907 P H LVDD I/O ERROR DETECTED BY LVM
C1348779 1229151907 I O SYSJ2 LOG I/O ERROR
E86653C3 1229151907 P H LVDD I/O ERROR DETECTED BY LVM
EA88F829 1229151907 I O SYSJ2 USER DATA I/O ERROR
E86653C3 1229151907 P H LVDD I/O ERROR DETECTED BY LVM
2E493F13 1229151807 P H hdisk5 ARRAY OPERATION ERROR
2E493F13 1229151807 P H hdisk5 ARRAY OPERATION ERROR
2E493F13 1229151807 P H hdisk5 ARRAY OPERATION ERROR
2E493F13 1229151807 P H hdisk5 ARRAY OPERATION ERROR
2E493F13 1229151807 P H hdisk5 ARRAY OPERATION ERROR
E86653C3 1229151807 P H LVDD I/O ERROR DETECTED BY LVM
E86653C3 1229151807 P H LVDD I/O ERROR DETECTED BY LVM
C1348779 1229151807 I O SYSJ2 LOG I/O ERROR
E86653C3 1229151807 P H LVDD I/O ERROR DETECTED BY LVM
EA88F829 1229151807 I O SYSJ2 USER DATA I/O ERROR
E86653C3 1229151807 P H LVDD I/O ERROR DETECTED BY LVM
CMGX_FS2:/# errpt -aj 2E493F13
---------------------------------------------------------------------------
LABEL: FCP_ARRAY_ERR2
IDENTIFIER: 2E493F13
Date/Time: Sat Dec 29 15:18:11 BEIST 2007
Sequence Number: 48905
Machine Id: 000D28EAD600
Node Id: CMGX_FS2
Class: H
Type: PERM
Resource Name: hdisk5
Resource Class: disk
Resource Type: array
Location: U787B.001.DNWC3B9-P1-C3-T1-W200500A0B826F8C3-L3000000000000
Description
ARRAY OPERATION ERROR
Probable Causes
ARRAY DASD DEVICE
Failure Causes
DISK DRIVE
DISK DRIVE ELECTRONICS
Recommended Actions
PERFORM PROBLEM DETERMINATION PROCEDURES
Detail Data
SENSE DATA
0600 0000 0000 0000 0000 0000 0000 0000 0000 0000 000B 1DDF 0102 0000 7000 0500
0000 0098 0000 0000 2500 0000 0000 0000 0100 0000 0000 0000 0000 0000 0000 8808
0099 9999 9900 0000 0000 0000 0000 0000 0000 3154 3635 3034 3433 3433 2020 2020
2020 0623 0500 0003 0600 0700 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000
0005 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000
0000 0000 040D A4F6 3132 3239 3037 2F30 3230 3331 3400 0000 0000 0000 0000 0000
0000 0000 2081 5000 F205 3402 0000 0000 0000 0000 0000 0000 1300 1300 0000 0000
0000 0000
---------------------------------------------------------------------------
LABEL: FCP_ARRAY_ERR2
IDENTIFIER: 2E493F13
Date/Time: Sat Dec 29 15:18:11 BEIST 2007
Sequence Number: 48904
Machine Id: 000D28EAD600
Node Id: CMGX_FS2
Class: H
Type: PERM
Resource Name: hdisk5
Resource Class: disk
Resource Type: array
Location: U787B.001.DNWC3B9-P1-C3-T1-W200500A0B826F8C3-L3000000000000
Description
ARRAY OPERATION ERROR
Probable Causes
ARRAY DASD DEVICE
Failure Causes
DISK DRIVE
DISK DRIVE ELECTRONICS
Recommended Actions
PERFORM PROBLEM DETERMINATION PROCEDURES
Detail Data
SENSE DATA
0600 0000 0000 0000 0000 0000 0000 0000 0000 0000 000B 1DDF 0102 0000 7000 0500
0000 0098 0000 0000 2500 0000 0000 0000 0100 0000 0000 0000 0000 0000 0000 8808
0099 9999 9900 0000 0000 0000 0000 0000 0000 3154 3635 3034 3433 3433 2020 2020
2020 0623 0500 0003 0600 0700 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000
0005 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000
0000 0000 040D A4EE 3132 3239 3037 2F30 3230 3331 3400 0000 0000 0000 0000 0000
0000 0000 2081 5000 F205 3402 0000 0000 0000 0000 0000 0000 1300 1300 0000 0000
0000 0000
---------------------------------------------------------------------------
LABEL: FCP_ARRAY_ERR2
IDENTIFIER: 2E493F13
Date/Time: Sat Dec 29 15:18:11 BEIST 2007
Sequence Number: 48903
Machine Id: 000D28EAD600
Node Id: CMGX_FS2
Class: H
Type: PERM
Resource Name: hdisk5
Resource Class: disk
Resource Type: array
Location: U787B.001.DNWC3B9-P1-C3-T1-W200500A0B826F8C3-L3000000000000
Description
ARRAY OPERATION ERROR
Probable Causes
ARRAY DASD DEVICE
Failure Causes
DISK DRIVE
DISK DRIVE ELECTRONICS
Recommended Actions
PERFORM PROBLEM DETERMINATION PROCEDURES
Detail Data
SENSE DATA
0600 0000 0000 0000 0000 0000 0000 0000 0000 0000 000B 1DDF 0102 0000 7000 0500
0000 0098 0000 0000 2500 0000 0000 0000 0100 0000 0000 0000 0000 0000 0000 8808
0099 9999 9900 0000 0000 0000 0000 0000 0000 3154 3635 3034 3433 3433 2020 2020
2020 0623 0500 0003 0600 0700 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000
0005 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000
0000 0000 040D A4E6 3132 3239 3037 2F30 3230 3331 3400 0000 0000 0000 0000 0000
0000 0000 2081 5000 F205 3402 0000 0000 0000 0000 0000 0000 1300 1300 0000 0000
0000 0000
---------------------------------------------------------------------------
LABEL: FCP_ARRAY_ERR2
IDENTIFIER: 2E493F13
Date/Time: Sat Dec 29 15:18:11 BEIST 2007
Sequence Number: 48902
Machine Id: 000D28EAD600
Node Id: CMGX_FS2
Class: H
Type: PERM
Resource Name: hdisk5
Resource Class: disk
Resource Type: array
Location: U787B.001.DNWC3B9-P1-C3-T1-W200500A0B826F8C3-L3000000000000
Description
ARRAY OPERATION ERROR
Probable Causes
ARRAY DASD DEVICE
Failure Causes
DISK DRIVE
DISK DRIVE ELECTRONICS
Recommended Actions
PERFORM PROBLEM DETERMINATION PROCEDURES
Detail Data
SENSE DATA
0600 0000 0000 0000 0000 0000 0000 0000 0000 0000 000B 1DDF 0102 0000 7000 0500
0000 0098 0000 0000 2500 0000 0000 0000 0100 0000 0000 0000 0000 0000 0000 8808
0099 9999 9900 0000 0000 0000 0000 0000 0000 3154 3635 3034 3433 3433 2020 2020
2020 0623 0500 0003 0600 0700 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000
0005 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000
0000 0000 040D A4DE 3132 3239 3037 2F30 3230 3331 3400 0000 0000 0000 0000 0000
0000 0000 2081 5000 F205 3402 0000 0000 0000 0000 0000 0000 1300 1300 0000 0000
0000 0000
---------------------------------------------------------------------------
LABEL: FCP_ARRAY_ERR2
IDENTIFIER: 2E493F13
Date/Time: Sat Dec 29 15:18:11 BEIST 2007
Sequence Number: 48901
Machine Id: 000D28EAD600
Node Id: CMGX_FS2
Class: H
Type: PERM
Resource Name: hdisk5
Resource Class: disk
Resource Type: array
Location: U787B.001.DNWC3B9-P1-C3-T1-W200500A0B826F8C3-L3000000000000
Description
ARRAY OPERATION ERROR
Probable Causes
ARRAY DASD DEVICE
Failure Causes
DISK DRIVE
DISK DRIVE ELECTRONICS
Recommended Actions
PERFORM PROBLEM DETERMINATION PROCEDURES
Detail Data
SENSE DATA
0600 0000 0000 0000 0000 0000 0000 0000 0000 0000 000B 1DDF 0102 0000 7000 0500
0000 0098 0000 0000 2500 0000 0000 0000 0100 0000 0000 0000 0000 0000 0000 8808
0099 9999 9900 0000 0000 0000 0000 0000 0000 3154 3635 3034 3433 3433 2020 2020
2020 0623 0500 0003 0600 0700 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000
0005 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000
0000 0000 040D A4D6 3132 3239 3037 2F30 3230 3331 3400 0000 0000 0000 0000 0000
0000 0000 2081 5000 F205 3402 0000 0000 0000 0000 0000 0000 1300 1300 0000 0000
0000 0000
2008-1-2 19:35
乐之陶
手工把Oracle_data3切换到控制器B后.无报错...数据库的控制文件用不了
2008-1-2 22:17
小猪
Probable Causes
ARRAY DASD DEVICE
Failure Causes
DISK DRIVE
DISK DRIVE ELECTRONICS
Recommended Actions
PERFORM PROBLEM DETERMINATION PROCEDURES
;P
2008-1-2 23:11
乐之陶
[quote]原帖由 [i]小猪[/i] 于 2008-1-2 22:17 发表 [url=http://www.loveunix.com/redirect.php?goto=findpost&pid=751877&ptid=80413][img]http://www.loveunix.com/images/common/back.gif[/img][/url]
Probable Causes
ARRAY DASD DEVICE
Failure Causes
DISK DRIVE
DISK DRIVE ELECTRONICS
Recommended Actions
PERFORM PROBLEM DETERMINATION PROCEDURES
;P [/quote]
是由于ds4700上控制器引起的.换到另一个就不报错了.具体要看明天恢复的情况