2008-1-6 18:43
失业中
ds4700疑问
OS:5306
HA:5.3
四块盘划了两个LUN,
在OS里面可以看到四个dac0,1,2,3
两个LUN都在dac0下
在sm下切到B控之后.过不了多久就切回来了
报错如下:
Date/Time: 1/6/08 10:59:29 AM
Sequence number: 864
Event type: 4011
Event category: Error
Priority: Critical
Description: Logical Drive not on preferred path due to ADT/RDAC failover
Event specific codes: 0/0/0
Component type: Controller
Component location: Controller in slot A
Logged by: Controller in slot A
Raw data:
4d 45 4c 48 02 00 00 00 60 03 00 00 00 00 00 00
11 40 18 01 11 44 80 47 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 01 00 00 00
08 00 00 00 08 00 00 00 ff ff ff ff 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 01 00 00 00 00 00 00 00
[[i] 本帖最后由 失业中 于 2008-1-6 18:51 编辑 [/i]]
2008-1-6 18:44
失业中
ds4700 profile:
PROFILE FOR STORAGE SUBSYSTEM: selfhelpsys (1/6/08 6:01:47 PM)
SUMMARY------------------------------
Number of controllers: 2
Number of arrays: 1
Total number of logical drives (includes an access logical drive): 3 of 1024 used
Number of standard logical drives: 2
Number of access logical drives: 1
Number of drives: 4
Supported drive types: Fibre (4)
Total hot spare drives: 1
Standby: 1
In use: 0
Access logical drive: LUN 31,31 (see Mappings section for details)
Default host OS: AIX (Host OS index 6)
Current configuration
Firmware version: 06.23.05.00
NVSRAM version: A1814D470R923V08
Pending configuration
Staged firmware download supported: Yes
Firmware version: None
NVSRAM version: None
Transferred on: None
Controller enclosure audible alarm: Disabled
NVSRAM configured for batteries: Yes
Start cache flushing at (in percentage): 80
Stop cache flushing at (in percentage): 80
Cache block size (in KB): 4
Media scan frequency (in days): 30
Failover alert delay (in minutes): 5
Feature enable identifier: 3130333034003035373939004720787B
Storage Subsystem worldwide name (ID): 600A0B800029F4F60000000047560F0A
Management software version: 09.23.G5.01
CONTROLLERS------------------------------
Number of controllers: 2
Controller in Enclosure 85, Slot A
Status: Online
Current configuration
Firmware version: 06.23.05.00
Appware version: 06.23.05.00
Bootware version: 06.23.05.00
NVSRAM version: A1814D470R923V08
Pending configuration
Firmware version: None
Appware version: None
Bootware version: None
NVSRAM version: None
Transferred on: None
Current ID (ALPA)
On drive channel 1: 125/0x1
On drive channel 2: 125/0x1
Replacement part number: 39M5896
Board ID: 3992
Submodel ID: 19
Product ID: 1814 FAStT
Product revision: 0916
Serial number: SG71010304
Date of manufacture: September 24, 2007
Vendor: IBM
Cache
Total data cache: 864 MB
Processor cache: 160 MB
Associated Logical Drives (* = Preferred Owner):
1*
Controller host name:
Remote login: Disabled
Ethernet port: 1
MAC address: 00:a0:b8:29:f4:f6
Network configuration: Static
IP address: 192.168.128.101
Subnet mask: 255.255.255.0
Gateway: 0.0.0.0
Ethernet port: 2
MAC address: 00:a0:b8:29:f4:f7
Network configuration: Static
IP address: 192.168.129.101
Subnet mask: 255.255.255.0
Gateway: 0.0.0.0
Drive interface: Fibre
Channel: 1
Current ID: 125/0x1
Maximum data rate: 4 Gbps
Current data rate: 2 Gbps
Data rate control: Switch
Link status: Up
Drive interface: Fibre
Channel: 2
Current ID: 125/0x1
Maximum data rate: 4 Gbps
Current data rate: 2 Gbps
Data rate control: Switch
Link status: Up
Host interface: Fibre
Channel: 1
Current ID: Not applicable/0xFFFFFFFF
Preferred ID: 0/0xEF
NL-Port ID: 0xFFFFFF
Maximum data rate: 4 Gbps
Current data rate: 4 Gbps
Data rate control: Auto
Link status: Down
Topology: Not Available
World-wide port name: 20:04:00:a0:b8:29:f4:f7
World-wide node name: 20:04:00:a0:b8:29:f4:f6
Part type: HPFC-5700 revision 5
Host interface: Fibre
Channel: 2
Current ID: Not applicable/0xFFFFFFFF
Preferred ID: 1/0xE8
NL-Port ID: 0xFFFFFF
Maximum data rate: 4 Gbps
Current data rate: 4 Gbps
Data rate control: Auto
Link status: Up
Topology: Fabric Attach
World-wide port name: 20:04:00:a0:b8:29:f4:f8
World-wide node name: 20:04:00:a0:b8:29:f4:f6
Part type: HPFC-5700 revision 5
Controller in Enclosure 85, Slot B
Status: Online
Current configuration
Firmware version: 06.23.05.00
Appware version: 06.23.05.00
Bootware version: 06.23.05.00
NVSRAM version: A1814D470R923V08
Pending configuration
Firmware version: None
Appware version: None
Bootware version: None
NVSRAM version: None
Transferred on: None
Current ID (ALPA)
On drive channel 1: 124/0x2
On drive channel 2: 124/0x2
Replacement part number: 39M5896
Board ID: 3992
Submodel ID: 19
Product ID: 1814 FAStT
Product revision: 0916
Serial number: SG73705799
Date of manufacture: September 21, 2007
Vendor: IBM
Cache
Total data cache: 864 MB
Processor cache: 160 MB
Associated Logical Drives (* = Preferred Owner):
2*
Controller host name:
Remote login: Disabled
Ethernet port: 1
MAC address: 00:a0:b8:32:d8:3a
Network configuration: Static
IP address: 192.168.128.102
Subnet mask: 255.255.255.0
Gateway: 0.0.0.0
Ethernet port: 2
MAC address: 00:a0:b8:32:d8:3b
Network configuration: Static
IP address: 192.168.129.102
Subnet mask: 255.255.255.0
Gateway: 0.0.0.0
Drive interface: Fibre
Channel: 1
Current ID: 124/0x2
Maximum data rate: 4 Gbps
Current data rate: 2 Gbps
Data rate control: Switch
Link status: Up
Drive interface: Fibre
Channel: 2
Current ID: 124/0x2
Maximum data rate: 4 Gbps
Current data rate: 2 Gbps
Data rate control: Switch
Link status: Up
Host interface: Fibre
Channel: 1
Current ID: Not applicable/0xFFFFFFFF
Preferred ID: 2/0xE4
NL-Port ID: 0xFFFFFF
Maximum data rate: 4 Gbps
Current data rate: 4 Gbps
Data rate control: Auto
Link status: Up
Topology: Fabric Attach
World-wide port name: 20:05:00:a0:b8:29:f4:f7
World-wide node name: 20:04:00:a0:b8:29:f4:f6
Part type: HPFC-5700 revision 5
Host interface: Fibre
Channel: 2
Current ID: Not applicable/0xFFFFFFFF
Preferred ID: 3/0xE2
NL-Port ID: 0xFFFFFF
Maximum data rate: 4 Gbps
Current data rate: 4 Gbps
Data rate control: Auto
Link status: Down
Topology: Not Available
World-wide port name: 20:05:00:a0:b8:29:f4:f8
World-wide node name: 20:04:00:a0:b8:29:f4:f6
Part type: HPFC-5700 revision 5
ARRAYS------------------------------
Number of arrays: 1
ARRAY 1 (RAID 5)
Array status: Online
Drive type: Fibre Channel
Enclosure loss protection: No
Current owner: Controller in slot A,B
Associated logical drives and free capacities:
LOGICAL DRIVE NAME CAPACITY
1 82 GB
2 190.464 GB
Associated drives (in piece order):
ENCLOSURE SLOT
85 1
85 2
85 3
STANDARD LOGICAL DRIVES------------------------------
SUMMARY
Number of standard logical drives: 2
See other Logical Drives sub-tabs for premium feature information.
NAME STATUS CAPACITY RAID LEVEL ARRAY
1 Optimal 82 GB 5 1
2 Optimal 190.464 GB 5 1
DETAILS
LOGICAL DRIVE NAME: 1
Logical Drive status: Optimal
Capacity: 82 GB (88,046,829,568 Bytes)
Logical Drive ID: 60:0a:0b:80:00:29:f4:f6:00:00:04:9c:47:69:e2:6a
Subsystem ID (SSID): 0
Associated array: 1
RAID level: 5
Drive type: Fibre Channel
Enclosure loss protection: No
Preferred owner: Controller in slot A
Current owner: Controller in slot A
Segment size: 128 KB
Modification priority: High
Read cache: Enabled
Write cache: Enabled
Write cache without batteries: Disabled
Write cache with mirroring: Enabled
Flush write cache after (in seconds): 10.00
Dynamic cache read prefetch: Enabled
Enable background media scan: Enabled
Media scan with redundancy check: Disabled
LOGICAL DRIVE NAME: 2
Logical Drive status: Optimal
Capacity: 190.464 GB (204,509,020,160 Bytes)
Logical Drive ID: 60:0a:0b:80:00:32:d8:3a:00:00:05:6b:47:69:e3:01
Subsystem ID (SSID): 1
Associated array: 1
RAID level: 5
Drive type: Fibre Channel
Enclosure loss protection: No
Preferred owner: Controller in slot B
Current owner: Controller in slot B
Segment size: 128 KB
Modification priority: High
Read cache: Enabled
Write cache: Enabled
Write cache without batteries: Disabled
Write cache with mirroring: Enabled
Flush write cache after (in seconds): 10.00
Dynamic cache read prefetch: Enabled
Enable background media scan: Enabled
Media scan with redundancy check: Disabled
MISSING LOGICAL DRIVES------------------------------
Number of missing logical drives: 0
DRIVES------------------------------
SUMMARY
Number of drives: 4
Current drive types: Fibre (4)
BASIC:
TRAY, SLOT STATUS CAPACITY CURRENT DATA RATE PRODUCT ID FIRMWARE VERSION
85, 1 Optimal 136.732 GB 2 Gbps HUS103014FLF21 JFQ8
85, 2 Optimal 136.732 GB 2 Gbps HUS103014FLF21 JFQ8
85, 3 Optimal 136.732 GB 2 Gbps HUS103014FLF21 JFQ8
85, 4 Optimal 136.732 GB 2 Gbps HUS103014FLF21 JFQ8
DRIVE CHANNELS:
TRAY, SLOT PREFERRED CHANNEL REDUNDANT CHANNEL
85, 1 1 2
85, 2 2 1
85, 3 1 2
85, 4 2 1
HOT SPARE COVERAGE:
The following arrays are not protected: None - All arrays are protected
Total hot spare drives: 1
Standby: 1
In use: 0
Standby drive at enclosure 85, slot 4 (Fibre, 136.732 GB)
Protects the following arrays: 1
DETAILS
Drive at Enclosure 85, Slot 1
Status: Optimal
Mode: Assigned
Raw capacity: 136.732 GB
Usable capacity: 136.232 GB
World-wide name: 20:00:00:00:87:a5:83:8c
Associated array: 1
PORT CHANNEL ID
0 1 0/0xEF
1 2 0/0xEF
Drive path redundancy: OK
Drive type: Fibre Channel
Speed: 10000 RPM
Current data rate: 2 Gbps
Product ID: HUS103014FLF21
Firmware version: JFQ8
Serial number: V5Y8Y5AA
Vendor: IBM-SSG
Date of manufacture: Not Available
Drive at Enclosure 85, Slot 2
Status: Optimal
Mode: Assigned
Raw capacity: 136.732 GB
Usable capacity: 136.232 GB
World-wide name: 20:00:00:00:87:a2:98:17
Associated array: 1
PORT CHANNEL ID
0 2 1/0xE8
1 1 1/0xE8
Drive path redundancy: OK
Drive type: Fibre Channel
Speed: 10000 RPM
Current data rate: 2 Gbps
Product ID: HUS103014FLF21
Firmware version: JFQ8
Serial number: V5Y4SLHA
Vendor: IBM-SSG
Date of manufacture: Not Available
Drive at Enclosure 85, Slot 3
Status: Optimal
Mode: Assigned
Raw capacity: 136.732 GB
Usable capacity: 136.232 GB
World-wide name: 20:00:00:00:87:a5:84:70
Associated array: 1
PORT CHANNEL ID
0 1 2/0xE4
1 2 2/0xE4
Drive path redundancy: OK
Drive type: Fibre Channel
Speed: 10000 RPM
Current data rate: 2 Gbps
Product ID: HUS103014FLF21
Firmware version: JFQ8
Serial number: V5Y8XWUA
Vendor: IBM-SSG
Date of manufacture: Not Available
Drive at Enclosure 85, Slot 4
Status: Optimal
Mode: Hot spare standby
Raw capacity: 136.732 GB
Usable capacity: 136.232 GB
World-wide name: 20:00:00:00:87:a5:b0:f9
Associated array: None
PORT CHANNEL ID
0 2 3/0xE2
1 1 3/0xE2
Drive path redundancy: OK
Drive type: Fibre Channel
Speed: 10000 RPM
Current data rate: 2 Gbps
Product ID: HUS103014FLF21
Firmware version: JFQ8
Serial number: V5Y7XPWA
Vendor: IBM-SSG
Date of manufacture: Not Available
DRIVE CHANNELS----------------------------
SUMMARY
CHANNEL STATUS CTRL A LINK CTRL B LINK
1 Optimal Up Up
2 Optimal Up Up
DETAILS
DRIVE CHANNEL 1
Status: Optimal
Max. Rate: 4 Gbps
Current Rate: 2 Gbps
Rate Control: Switch
Controller A link status: Up
Controller B link status: Up
DRIVE COUNTS
Total # of attached drives: 4
Connected to: Controller A
Attached drives: 4
Drive enclosure: 85 (4 drives)
CUMULATIVE ERROR COUNTS
Controller A
Baseline time set: 12/20/07 10:06:17 PM
Sample period (days, hh:mm:ss): 16 days, 20:20:06
Controller detected errors: 0
Drive detected errors: 0
Timeout errors: 0
Link down errors: 0
Total I/O count: 1759023
Controller B
Baseline time set: 12/20/07 10:06:17 PM
Sample period (days, hh:mm:ss): 16 days, 20:20:06
Controller detected errors: 0
Drive detected errors: 0
Timeout errors: 0
Link down errors: 0
Total I/O count: 1724766
DRIVE CHANNEL 2
Status: Optimal
Max. Rate: 4 Gbps
Current Rate: 2 Gbps
Rate Control: Switch
Controller A link status: Up
Controller B link status: Up
DRIVE COUNTS
Total # of attached drives: 4
Connected to: Controller B
Attached drives: 4
Drive enclosure: 85 (4 drives)
CUMULATIVE ERROR COUNTS
Controller A
Baseline time set: 12/20/07 10:06:17 PM
Sample period (days, hh:mm:ss): 16 days, 20:20:06
Controller detected errors: 0
Drive detected errors: 0
Timeout errors: 0
Link down errors: 0
Total I/O count: 1700247
Controller B
Baseline time set: 12/20/07 10:06:17 PM
Sample period (days, hh:mm:ss): 16 days, 20:20:06
Controller detected errors: 0
Drive detected errors: 0
Timeout errors: 0
Link down errors: 0
Total I/O count: 1684709
ENCLOSURES------------------------------
Controller/Drive Enclosure Overall Component Information
Enclosure audible alarm: Disabled
Enclosure path redundancy: OK
Current drive types: Fibre channel
Part number: PN 42D3314
Serial number: SN SG73444617
Vendor: VN IBM
Date of manufacture: September 1, 2007
2 Batteries Detected
Battery status: Optimal
Location: Controller A
Age: 90 days
Days until replacement: 1,169 days
Replacement part number: PN 41Y0679
Serial number: SN 040748965
Vendor: VN IBM
Date of manufacture: January 1, 2007
Battery status: Optimal
Location: Controller B
Age: 90 days
Days until replacement: 1,169 days
Replacement part number: PN 41Y0679
Serial number: SN 040748966
Vendor: VN IBM
Date of manufacture: January 1, 2007
4 SFPs Detected
SFP status: Optimal
Attached to: Host-side of controller B
Location: Channel 1
Supported data rate(s): 1 Gbps, 2 Gbps, 4 Gbps
Link length: Intermediate
Connector: LC
Transmitter type: Shortwave Laser w/o OFC
Transmission media: TM Multi-mode 50m(M5) TM Multi-mode 62.5m(M6)
IEEE company ID: 00 04 85
Revision: 1
Part number: PLRXPLVESG464N
Serial number: C738SV1NV
Vendor: PICOLIGHT
Date of manufacture: September 19, 2007
SFP status: Optimal
Attached to: Host-side of controller B
Location: Channel 2
Supported data rate(s): 1 Gbps, 2 Gbps, 4 Gbps
Link length: Intermediate
Connector: LC
Transmitter type: Shortwave Laser w/o OFC
Transmission media: TM Multi-mode 50m(M5) TM Multi-mode 62.5m(M6)
IEEE company ID: 00 04 85
Revision: 1
Part number: PLRXPLVESG464N
Serial number: C738SV1NW
Vendor: PICOLIGHT
Date of manufacture: September 19, 2007
SFP status: Optimal
Attached to: Host-side of controller A
Location: Channel 1
Supported data rate(s): 1 Gbps, 2 Gbps, 4 Gbps
Link length: Intermediate
Connector: LC
Transmitter type: Shortwave Laser w/o OFC
Transmission media: TM Multi-mode 50m(M5) TM Multi-mode 62.5m(M6)
IEEE company ID: 00 04 85
Revision: 1
Part number: PLRXPLVESG464N
Serial number: C738SV1PV
Vendor: PICOLIGHT
Date of manufacture: September 19, 2007
SFP status: Optimal
Attached to: Host-side of controller A
Location: Channel 2
Supported data rate(s): 1 Gbps, 2 Gbps, 4 Gbps
Link length: Intermediate
Connector: LC
Transmitter type: Shortwave Laser w/o OFC
Transmission media: TM Multi-mode 50m(M5) TM Multi-mode 62.5m(M6)
IEEE company ID: 00 04 85
Revision: 1
Part number: PLRXPLVESG464N
Serial number: C738SV1PW
Vendor: PICOLIGHT
Date of manufacture: September 19, 2007
2 Power-Fan Canisters Detected
Left Power-fan canister status: Optimal
Part number: PN 42D3346
Serial number: SN YPT073500757
Vendor: VN IBM
Date of manufacture: August 1, 2007
Right Power-fan canister status: Optimal
Part number: PN 42D3346
Serial number: SN YPT073500758
Vendor: VN IBM
Date of manufacture: August 1, 2007
2 Power Supplies Detected
Power supply status: Optimal
Location: Power-fan canister (left)
Power supply status: Optimal
Location: Power-fan canister (right)
2 Fans Detected
Fan Status: Optimal
Location: Power-fan canister (left)
Fan Status: Optimal
Location: Power-fan canister (right)
4 Temperature Sensors Detected
Temperature sensor status: Optimal
Location: Controller A
Temperature sensor status: Optimal
Location: Controller B
Temperature sensor status: Optimal
Location: Power-fan canister (left)
Temperature sensor status: Optimal
Location: Power-fan canister (right)
MAPPINGS (Storage Partitioning - Enabled (1 of 2 used))-------------------
VOLUME NAME LUN CONTROLLER ACCESSIBLE BY VOLUME STATUS
Access Logical Drive 31 A,B Default Group Optimal
Access Logical Drive 31 A,B Host Group SF Optimal
1 1 A Host Group SF Optimal
2 2 B Host Group SF Optimal
TOPOLOGY DEFINITIONS
DEFAULT GROUP
Default type: AIX
HOST GROUP SF
Host: datasvr
Host Port: 10:00:00:00:c9:6a:b4:cc
Alias: orc2
Type: AIX
Host Port: 10:00:00:00:c9:6a:d3:38
Alias: orc1
Type: AIX
Host Port: 10:00:00:00:c9:6a:fe:e6
Alias: data2
Type: AIX
Host Port: 10:00:00:00:c9:6a:fe:e8
Alias: data1
Type: AIX
NVSRAM HOST TYPE DEFINITIONS
HOST TYPE ADT STATUS ASSOCIATED INDEX
AIX Disabled 6 (Default)
AIX-ADT/AVT Enabled 4
DEFAULT Disabled 0
HP-UX Enabled 7
IBM TS SAN VCE Enabled 12
Irix Disabled 10
LNXCLVMWARE Disabled 13
Linux Enabled 5
Netware Failover Enabled 11
Solaris Disabled 8
Solaris (with Veritas DMP) Enabled 14
Unused1 Disabled 1
Windows 2000/Server 2003 Clustered Disabled 3
Windows 2000/Server 2003 Clustered (supports DMP) Enabled 15
Windows 2000/Server 2003 Non-Clustered Disabled 2
Windows 2000/Server 2003 Non-Clustered (supports DMP) Enabled 9