2008-2-20 13:18
15al
storage manager 里面的报警,请各位老大指教
这是我收集的event log中的报警,不清楚是怎么回事,里面的各个部件均完好:Date/Time: 2/16/08 10:13:19 AM
Sequence number: 104730
Event type: 280D
Event category: Internal
Priority: Critical
Description: Drive enclosure component failed
Event specific codes: 0/0/0
Component type: Enclosure Component (ESM, GBIC/SFP, Power Supply, or Fan)
Component location: Enclosure 0
Raw data:
4d 45 4c 48 02 00 00 00 1a 99 01 00 00 00 00 00
0d 28 47 01 bf 46 b6 47 00 00 00 00 00 00 00 00
49 00 00 00 00 00 00 00 01 00 00 00 04 00 00 00
07 00 00 00 07 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 01 00 00 00 01 08 00 00
04 00 00 08 00 00 00 00
2008-2-20 13:22
phonfex
你看一下.诊断那里有没有报错?
2008-2-20 13:24
wui_123
检查下 光千卡 卡有问题吧
2008-2-20 13:34
15al
回复 #2 phonfex 的帖子
没有报错,NO FAILED。
2008-2-20 13:35
15al
回复 #3 wui_123 的帖子
如果光线卡有问题的话,那业务应该受到影响啊,现在业务都正常啊
2008-2-20 13:42
jnpiero
刚出的错么?阵列有没有断电再加电过?
2008-2-20 13:50
15al
回复 #6 jnpiero 的帖子
前几天的问题,断电后会出现这样的报错么?
2008-2-20 14:04
老农
2月16日掉过电吧。注意看日期啊
2008-2-20 14:27
15al
回复 #8 老农 的帖子
农哥,这个怎么看出来是掉过电的呢?
2008-2-20 15:23
ChaosLegion
Component type: Enclosure Component (ESM, GBIC/SFP, Power Supply, or Fan)
推断的吧